  First of all always check a condition of a safety lock.   | 
 
 
 1. Disconnect an electrical wiring from horn horns.   2. For check of serviceability of functioning of a horn give battery tension on one of its plugs. Ground the second plug (use wires crossing points). If the horn does not publish a sound signal, replace it.  
 
| 
 | 
  3. At correct sounding of a horn check presence of tension on the horn socket at the pressed button of management. If tension takes place, check a condition of grounding.   | 
 
 
 4. If tension is absent, check the corresponding relay (see the Section of the Relay - the general information and check of serviceability of functioning).   5. If the relay as it should be, check serviceability of giving of food for the relay of power and a contour of management. At violation of giving of food in any of contours check a condition of an electrical wiring on the site of a chain between the relay and the assembly block of safety locks.   6. If tension regularly moves in both contours, press the button of a horn and check conductivity of the switch for weight. In the absence of conductivity check a chain for break. If a chain as it should be, replace the horn switch.   7. In the absence of conductivity of the switch check for break and short circuit a chain on the site between the relay and the switch.   |